• On October 16th, Mr. Formosa LU, president of FCC, is once again invited by the event organizers to the ribbon-cutting ceremony of the 36th edition of Indonesia Hospital Expo in Jakarta, Indonesia

  • We will be present at Arab Health 2024 and MEDLAB Middle East 2024 in Dubai! Contact us for more info on these two mega shows

  • Since 2023, Medtrade is single event, held in Dallas, next edition on March 27-28, 2024, contact us for more info!

  • KiMES Seoul will be held in Seoul on 2024-03-14 to 2024-03-17 - Contact us for more info!

  • OTWorld is held every two years in Leipzig, Germany. Next edition 2024-05-17 to 2024-05-17 don't miss the world's biggest orthopedics congress!

Home / Home Care / Pre-program TENS
Ref.Number: GM350PP
Pre-program TENS
Detail
The new two independent channels stimulator. You can use P2 for channel 1 and use P6 for channel 2 at the same time for different treatment area. It is good for different pain and area.
The pre-program mode is easy operated by user.

Channel: Dual, isolated between channels
Pulse intensity: Adjustable 0-80mA peak into 500 Ω load each channel, constant current
Pulse Rate: 2Hz-120Hz (pre-set).
Pulse Width: 60μs - 260μs (pre-set).
Auto Lock: To prevent the user from changing any fixed parameters. Auto set if no key be pressed more than 10 sec.
Compliance meter Show the treatment time in hours.
Timer: 15, 30, 60 minute and continue selectable
LCD: Shows CH1/CH2 intensity, timer, CH1/CH2.mode
Function Modes for each Channel:
P1: Continuous mode, 15 Hz.
P2: Burst mode..
P3: Continuous mode, 120 Hz.
P4: D-D (Disperse-Dense Modulation), 2 HZ/15Hz.
P5: D-D (Disperse-Dense Modulation), 2 HZ/100Hz.
P6: Width Modulation mode.
P7: MR (Rate modulation) mode.
P8: Continuous mode, 80 Hz.
P9: P1->P2->P3->P4->P5->P6->P7 in cycle, 1 min/Mode.

PS. The mode content:
Burst: Cycle Bursts, 2Bursts/sec, 9pulses/Burst, 100Hz.
Continuous mode: Continue output
Modulated Width. Pulse width is automatically varied in an interval of 6 seconds. The modulation range of pulse width is from 140μs to 260μs, then returns to 140μs in 6 sec cycle time.
Rate modulation. MR consists of alternating pulse rate from 3 Hz to 100 Hz then return to 3 Hz in 6 sec cycle time.

Wave form: Asymmetrical Bi-phasic square pulse.
Voltage: 0-110 Volt (Open Circuit).
Max charge per pulse: 21 micro-coulombs
Power Source: 9-Volt Battery.
Dimensions: 122mm(H) ×65mm(W) ×25mm(T).
Weight: 140grams (battery included).
All electrical specifications are ±10% 500Ω load.