• On October 16th, Mr. Formosa LU, president of FCC, is once again invited by the event organizers to the ribbon-cutting ceremony of the 36th edition of Indonesia Hospital Expo in Jakarta, Indonesia

  • We will be present at Arab Health 2024 and MEDLAB Middle East 2024 in Dubai! Contact us for more info on these two mega shows

  • Since 2023, Medtrade is single event, held in Dallas, next edition on March 27-28, 2024, contact us for more info!

  • KiMES Seoul will be held in Seoul on 2024-03-14 to 2024-03-17 - Contact us for more info!

  • OTWorld is held every two years in Leipzig, Germany. Next edition 2024-05-17 to 2024-05-17 don't miss the world's biggest orthopedics congress!

Home / Pads / PTCA Balloon Dilatation Catheter-Rapid Exchange
Ref.Number: BT-BC-R4 Series
PTCA Balloon Dilatation Catheter-Rapid Exchange
Specifications
Material: PBAT
Color: Clear
Size: 2x10mm - 3x20mm
Other: none
Detail

 






    • Bioteque's Rapid Exchange (Mono-rail) balloon meet the challenge to reach a equilibrium between various performance characteristics – pushability, trackability, torqueability, kink performance in order to provide clinical versatility in coronary artery use.





 






    • Semi-compliance nylon material balloon material exhibit relatively high tensile strength, controlled compliance.





 






    • Typical triple balloon refolding characteristics.





 




    • The effective length of balloon catheter are available in 135cm.



 






    • Marks on the proximal portion of the catheter shaft at 90cm and 100cm from the distal tip are for  physician reference.





 






    • Hub configuration:Enhanded strain relief design prevent kinking, transparent hub facilitates easy  air bubble detection.





 






    • Reinforced mid shaft design provides flexibility and additional support enhance overall pushibility to lead physician to the target lesion.





 






    • Guidewire compatibility:0.014”.





 






    • Specially designed radiopaque tapered tip for advanced crossability and provide x-ray visibility of  the catheter, the flexible tip is closely meshed with the guide wire, fish-mouth Phenomenon is   minimized.







































































































































































































































































































































    • Product CodeBalloon Diameter (mm)Balloon Length (mm)Catheter Length (cm)Recommended Guidewire Size (inch)Nominal Pressure (atm)Rated Burst Pressure (atm)Guiding Catheter Size (Fr)
      BT-BC-R4-2-10-1352.00101350.0147165
      BT-BC-R4-2-15-1352.00151350.0147165
      BT-BC-R4-2-20-1352.00201350.0147165
      BT-BC-R4-225-10-1352.25101350.0147165
      BT-BC-R4-225-15-1352.25151350.0147165
      BT-BC-R4-225-20-1352.25201350.0147165
      BT-BC-R4-25-10-1352.50101350.0145165
      BT-BC-R4-25-15-1352.50151350.0145165
      BT-BC-R4-25-20-1352.50201350.0145165
      BT-BC-R4-275-10-1352.75101350.0145165
      BT-BC-R4-275-15-1352.75151350.0145165
      BT-BC-R4-275-20-1352.75201350.0145165
      BT-BC-R4-3-10-1353.00101350.0145165
      BT-BC-R4-3-15-1353.00151350.0145165
      BT-BC-R4-3-20-1353.00201350.0145165
              
      BT-BC-R4-2-10-1452.00101450.0147165
      BT-BC-R4-2-15-1452.00151450.0147165
      BT-BC-R4-2-20-1452.00201450.0147165
      BT-BC-R4-225-10-1452.25101450.0147165
      BT-BC-R4-225-15-1452.25151450.0147165
      BT-BC-R4-225-20-1452.25201450.0147165
      BT-BC-R4-25-10-1452.50101450.0145165
      BT-BC-R4-25-15-1452.50151450.0145165
      BT-BC-R4-25-20-1452.50201450.0145165
      BT-BC-R4-275-10-1452.75101450.0145165
      BT-BC-R4-275-15-1452.75151450.0145165
      BT-BC-R4-275-20-1452.75201450.0145165
      BT-BC-R4-3-10-1453.00101450.0145165
      BT-BC-R4-3-15-1453.00151450.0145165
      BT-BC-R4-3-20-1453.00201450.0145165